Different Types of Door-Opening Motions as Contributing Factors to Containment Failures in Hospital Isolation Rooms
2013
PLOS ONE
Journal Article
Issue 6
Volume 8
Pages e66663
Author(s): Tang, J. W., Nicolle, A., Pantelic, J., Klettner, C. A., Su, R., Kalliomaki, P., Saarinen, P., Koskela, H., Reijula, K., Mustakallio, P., Cheong, D. K. W., Sekhar, C., Tham, K. W., Costa, C.
When under negative pressure, hospital isolation rooms are essential for both the containment of patients emitting airborne infectious agents as well as the protection of other patients from these agents. A plethora of different doors are used in the construction of these rooms, but relatively few studies have analyzed how certain door-opening motions and the passage of healthcare workers through these doors can affect the overall performance of isolation rooms.
Added December 2016
Measurement of ventilation and airborne infection risk in large naturally ventilated hospital wards
2013
Building and Environment
Journal Article
Author(s): Gilkeson, C. A., Camargo-Valero, M. A., Pickin, L. E., Noakes, C. J.
In healthcare environments, the transmission of airborne pathogens is a matter of concern. Ventilation has been identified as one of the key factors in the risk of infection. The authors indicate that most of the evidence on ventilation and infection risk has been in controlled spaces like operating rooms and isolation rooms, and that naturally ventilated spaces like wards have not been studied. They conducted a series of experiments in an unused ward to measure the transmission of pathogens in conditions of natural ventilation, mechanical ventilation, and no ventilation.
Added March 2015
Recommended standards for newborn ICU design, eighth edition
2013
Journal of Perinatology
Journal Article
Issue S1
Volume 33
Pages S2-S16
Author(s): White, R. D., Smith, J. A., Shepley, M. M.
Added November 2014
Utilizing Integrated Facility Design to Improve the Quality of a Pediatric Ambulatory Surgery Center
2013
Pediatric Anesthesia
Journal Article
Author(s): Pelly, N., Zeallear, B., B., Reed, M., Martin, L.
Integrated Facility Design (IFD) comes from the Toyota 3P (Production, Preparation, Process) program used to reduce initial cost, while accelerating development time.
Added May 2014
Life Safety Code Comparison
2013
American Society for Healthcare Engineering
Journal Article
Author(s): Crowley, M. A., Harper, J. E.
Added May 2014
Review of the Literature: Acuity-Adaptable Patient Room
2013
Critical Care Nursing Quarterly
Journal Article
Issue 2
Volume 36
Pages 251–271
Author(s): Bonuel, N. , Cesario, S.
Acuity-adaptable rooms allow patients to stay in one room from the time they are admitted to when they leave, regardless of their acuity level. These specially equipped private rooms are staffed by nurses who have the skills and training to support the complete range of care for patients with similar conditions or disease processes. The rooms are larger in size than a regular hospital room to accommodate various patients’ needs as their condition changes, such as critical care equipment, additional staff, procedures, and family members.
Added March 2014