Numerical investigation of different airflow schemes in a real operating theatre
2015
Journal of Biomedical Science and Engineering
Journal Article
Issue 02
Volume 8
Pages 73-89
Author(s): Balocco, C., Petrone, G., Cammarata, G.
Efficiency of a ventilation system in providing an effective airflow that contributes to the removal of contaminants (pathogens, anesthetic gases, carbon dioxide, etc.) is crucial to alleviating the risk of surgical site infection, protecting patients and staff from infection, and in ensuring thermal comfort to the occupants in operating theatres (OTs).
Added February 2015
Factors influencing evaluation of patient areas, work spaces, and staff areas by healthcare professionals
2013
Indoor and Built Environment
Journal Article
Author(s): Sadatsafavi, H., Walewski, J., Shepley, M. M.
One important element of high-quality healthcare delivery is a motivated and satisfied staff. Healthcare executives should regularly examine the factors that influence clinicians’ perceptions of satisfaction and quality so that necessary changes can be addressed.
Added November 2014
Does a mobile laminar airflow screen reduce bacterial contamination in the operating room? A numerical study using computational fluid dynamics technique
2014
Patient Safety in Surgery
Journal Article
Author(s): Sadrizadeh, S., Tammelin, A., Nielsen, P. V., Holmberg, S.
Surgical-site infections (SSIs) can increase patient morbidity and mortality and extend hospitalization time. Operating room (OR) personnel are the main source of airborne bacteria; a person releases roughly 104 skin scales per minute while walking, 10% of which carry bacteria, although up to 12 times as many microorganisms may be discharged depending on the individual and situation. Bacteria in the OR might contaminate a surgical wound through contact with the air or through contaminated surgical instruments.
Added November 2014
Thermal comfort of the surgical staff in the operating room
2014
Building and Environment
Journal Article
Author(s): van Gaever, R., Jacobs, V. A., Diltoer, M., Peeters, L., Vanlanduit, S.
Added November 2014
Experimental tests of copper components in ventilation systems for microbial control
2012
HVAC&R Research
Journal Article
Issue 1
Volume 19
Pages 53-62
Author(s): Feigley, C., Khan, J., Salzberg, D., Hussey, J., Attaway, H., Steed, L., Schmidt, M., Michels, H.
Added November 2014
Functional recovery of a resilient hospital type
2014
Building Research & Information
Journal Article
Issue 6
Volume 42
Pages 657-684
Author(s): Short, C. A., Noakes, C. J., Gilkeson, C. A., Fair, A.
Added November 2014
Environmental contamination and hospital acquired infection: factors that are easily overlooked
2015
Indoor Air
Journal Article
Issue 5
Volume 25
Pages 462-74
Author(s): Beggs, C. B., Knibbs, L. D., Johnson, G. R., Morawska, L.
Added November 2014
Aspergillosis in Four Renal Transplant Recipients: Diagnosis and Effective Treatment with Amphotericin B
1972
Annals of Internal Medicine
Journal Article
Author(s): Burton, J. R, Zachery, J. B, Bessin, R.
Added September 2014
Physical Environment Provisions of USP “Pharmaceutical Compounding—Sterile Preparations”
2012
American Society for Healthcare Engineering
Journal Article
Author(s): Beebe, C.
USP <797> reports standards and policies for all physical environments in which compounded sterile preparations (CSPs) are prepared, packaged, and stored. The standards apply specifically to people who prepare CSPs and must take care to reduce the risk of contamination from their behaviors, hygiene, and clothing (i.e., garb). Clinical workers whose work lies within this realm must be individually trained and evaluated to maintain the standards and reduce microbial contamination that results from contact.
Added September 2014
Process Simulation during the Design Process Makes the Difference: Process Simulations Applied to a Traditional Design
2013
HERD: Health Environments Research & Design Journal
Journal Article
Issue 2
Volume 6
Pages 58-76
Author(s): Traversari, R., Goedhart, R., Schraagen, J. M.
Minimal evidence exists regarding the design implications of using process simulation to assist in the process of designing new operating room (OR) layouts. While the traditional design process for OR layout does incorporate the experiences and insights of users, functionality testing of the OR environment is usually conducted post occupancy.
Added September 2014
Post-Occupancy Evaluation of a Transformed Nursing Home: The First Four Green House Settings
2013
Journal of Housing For the Elderly
Journal Article
Issue 4
Volume 23
Pages 304-334
Author(s): Cutler, L. J., Kane, R. A.
To study how well the physical environments of four Green Houses® served the residents, staff, and visitors and to develop recommendations for similar small-house nursing home projects. Longitudinal post-occupancy evaluation of four houses using mixed-methods, including behavioral mapping, checklist ratings of individual bedrooms and bathrooms, place-centered time scans, environmental tracers,...
Added September 2014
Wound ventilation with ultraclean air for prevention of direct airborne contamination during surgery
2004
Infection Control & Hospital Epidemiology
Journal Article
Issue 4
Volume 25
Pages 297-301
Author(s): Persson, M., van der Linden, J.
Added September 2014
The risk of airborne cross-infection in a room with vertical low-velocity ventilation
2012
Indoor Air
Journal Article
Issue 1
Volume 23
Pages 62-73
Author(s): Olmedo, I., Nielsen, P. V., de Adana, M. R., Jensen, R. L.
Added September 2014
A decade of adult intensive care unit design: a study of the physical design features of the best-practice examples
2006
Critical Care Nursing Quarterly
Journal Article
Issue 4
Volume 29
Pages 282-311
Author(s): Rashid, M., Abushousheh, A.
This article reports a study of the physical design characteristics of a set of adult intensive care units (ICUs), built between 1993 and 2003. These ICUs were recognized as the best-practice examples by the Society of Critical Care Medicine, the American Association of Critical Care Nurses, and the American Institute of Architects.
Added July 2014
Perceived hospital environment quality indicators: A study of orthopaedic units
2006
Journal of Environmental Psychology
Journal Article
Issue 4
Volume 26
Pages 321-334
Author(s): Fornara, F., Bonaiuto, M., Bonnes, M.
The field of healthcare design has increasingly recognized the need for building environments that are more ‘‘user-centered,’’ but spatial–physical features have not typically been included in assessment surveys on patient satisfaction.
Added July 2014
Life Safety Code Comparison
2013
American Society for Healthcare Engineering
Journal Article
Author(s): Crowley, M. A., Harper, J. E.
Added May 2014
Physical Environment: The Major Determinant Towards the Creation of a Healing Environment?
2011
Procedia-Social and Behavioral Sciences
Journal Article
Volume 30
Pages 1951-1958
Author(s): Abbas, M. Y., Ghazali, R.,
Prior research suggests that the pediatric population’s heightened perception of the quality of the physical environment can have an impact on the creation of a healing environment.
Added April 2014
Quality Physical Environment in Paediatric Wards: Designer’s Creation Versus Users’ Satisfaction
2012
Procedia - Social and Behavioral Sciences
Journal Article
Author(s): Ghazali, R., Abbas, M. Y.
Prior research has revealed that an optimal healing environment can enhance a child’s quality of life by supporting the healing process. However, little has been done to identify specific design features within an optimal healing environment that either impede or aid the healing process.
Added April 2014
Nurses’ Perception of Single-Occupancy Versus Multioccupancy Rooms in Acute Care Environments: An Exploratory Comparative Assessment
2006
Applied Nursing Research
Journal Article
Issue 3
Volume 19
Pages 118-125
Author(s): Chaudhury, H., Mahmood, A., Valente, M.
As people are living longer and the baby boomers age, the demand for hospital beds will increase. As new facilities are built to handle this influx of patients, the challenge for hospital designers and administrators is to design patient rooms that promote therapeutic goals, foster positive patient outcomes, and function as intensive care rooms. Recent research suggests that single-occupancy rooms are more suitable for infection control and patient care than multioccupancy rooms. However, no research has been done about nursing staff members’ perception of single-occupancy and multioccupancy patient rooms in acute care settings as it relates to patient care.
Added April 2014
Enhancing the traditional hospital design process: a focus on patient safety
March 2004
The Joint Commission Journal on Quality and Safety
Journal Article
Issue 3
Volume 30
Pages 115-24
Author(s): Reiling, J.G., Knutzen, B.L., Wallen, T.K., McCullough, S. , Miller, R., Chernos, S.
The current study is an overview of innovative system engineering and patient safety factors, named as the Synergy model that a hospital system utilized to design their new facility.
Added April 2014